VACON 20X DRIVE

VACON 20X DRIVE

Application: designed for control of pumps, fans, conveyors, machinery, solar application
Frame: MU2 ÷ 3
Power: 0.75 ÷ 7.5kW
Overload: 150% / 1min
Current: 3.7 ÷ 16A
Voltage: 208 ÷ 240VAC (1~)208 ÷ 240VAC (3~)380 ÷ 480VAC (3~)
Phase Number1~ or  3~
Input: AI1: voltage or currentAI2: voltage or currentDI1 -DI6+10V Ref.
Output:  1 x AO1 x DO (open collector)+24V outRS485 (receiver/transmitter)
Output Frequency: 0 ÷ 320Hz
Ambient Temperature: -10 ÷ 50°C
Brake Chopper: integrated
Safe Torque OFF:SIL3 according EN61800-3 
Emissions:EMC level C2 (3 phase), C1 (1 phase)
Protection Class:IP66 / Type 4X outdoor
Approvals: SIL3
 
Application: designed for control of pumps, fans, conveyors, machinery, solar application
Frame: MU2 ÷ 3
Power: 0.75 ÷ 7.5kW
Overload: 150% / 1min
Current: 3.7 ÷ 16A
Voltage: 208 ÷ 240VAC (1~)208 ÷ 240VAC (3~)380 ÷ 480VAC (3~)
Phase Number1~ or  3~
Input: AI1: voltage or currentAI2: voltage or currentDI1 -DI6+10V Ref.
Output:  1 x AO1 x DO (open collector)+24V outRS485 (receiver/transmitter)
Output Frequency: 0 ÷ 320Hz
Ambient Temperature: -10 ÷ 50°C
Brake Chopper: integrated
Safe Torque OFF:SIL3 according EN61800-3 
Emissions:EMC level C2 (3 phase), C1 (1 phase)
Protection Class:IP66 / Type 4X outdoor
Approvals: SIL3
VACON 20 X drives, 380 ÷ 480V, 3~ (3~MOTOR), IP66/Type 4X, EMC Class C2, No Keypad
SKU:DescriptionPower, [kW]Current, [A]Frame
VACON0020-3L-0003-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase0.752.4MU2
VACON0020-3L-0004-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase1.13.3MU2
VACON0020-3L-0005-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase1.54.3MU2
VACON0020-3L-0006-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase2.25.6MU2
VACON0020-3L-0008-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase37.6MU2
VACON0020-3L-0009-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase49MU3
VACON0020-3L-0012-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase5.512MU3
VACON0020-3L-0016-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase7.516MU3

 VACON 20 X drives, 208 ÷ 230V, 1~ (3~MOTOR), IP66/Type 4X, EMC Class C1, No Keypad

SKU:DescriptionPower, [kW]Current, [A]Frame
VACON0020-1L-0004-2-XVACON 20X drive, 208 ÷ 230V, IP660.753.7MU2
VACON0020-1L-0005-2-XVACON 20X drive, 208 ÷ 230V, IP661.14.8MU2
VACON0020-1L-0007-2-XVACON 20X drive, 208 ÷ 230V, IP661.57MU2

DANFOSS – VACON 20 X drives, 208 ÷ 230V, 3~ (3~MOTOR), IP66/Type 4X, EMC Class C2, No Keypad

SKU:DescriptionPower, [kW]Current, [A]Frame
VACON0020-3L-0004-2-XVACON 20X drive, 208 ÷ 230V, IP66, 3~ phase0.753.7MU2
VACON0020-3L-0005-2-XVACON 20X drive, 208 ÷ 230V, IP66, 3~ phase1.14.8MU2
VACON0020-3L-0007-2-XVACON 20X drive, 208 ÷ 230V, IP66, 3~ phase1.57MU2
VACON0020-3L-0011-2-XVACON 20X drive, 208 ÷ 230V, IP66, 3~ phase2.211MU3
VACON0020-3L-0012-2-XVACON 20X drive, 208 ÷ 230V, IP66, 3~ phase312.5MU3
VACON0020-3L-0017-2-XVACON 20X drive, 208 ÷ 230V, IP66, 3~ phase417.5MU3
Application: designed for control of pumps, fans, conveyors, machinery, solar application
Frame: MU2 ÷ 3
Power: 0.75 ÷ 7.5kW
Overload: 150% / 1min
Current: 3.7 ÷ 16A
Voltage: 208 ÷ 240VAC (1~)208 ÷ 240VAC (3~)380 ÷ 480VAC (3~)
Phase Number1~ or  3~
Input: AI1: voltage or currentAI2: voltage or currentDI1 -DI6+10V Ref.
Output:  1 x AO1 x DO (open collector)+24V outRS485 (receiver/transmitter)
Output Frequency: 0 ÷ 320Hz
Ambient Temperature: -10 ÷ 50°C
Brake Chopper: integrated
Safe Torque OFF:SIL3 according EN61800-3 
Emissions:EMC level C2 (3 phase), C1 (1 phase)
Protection Class:IP66 / Type 4X outdoor
Approvals: SIL3
 
Application: designed for control of pumps, fans, conveyors, machinery, solar application
Frame: MU2 ÷ 3
Power: 0.75 ÷ 7.5kW
Overload: 150% / 1min
Current: 3.7 ÷ 16A
Voltage: 208 ÷ 240VAC (1~)208 ÷ 240VAC (3~)380 ÷ 480VAC (3~)
Phase Number1~ or  3~
Input: AI1: voltage or currentAI2: voltage or currentDI1 -DI6+10V Ref.
Output:  1 x AO1 x DO (open collector)+24V outRS485 (receiver/transmitter)
Output Frequency: 0 ÷ 320Hz
Ambient Temperature: -10 ÷ 50°C
Brake Chopper: integrated
Safe Torque OFF:SIL3 according EN61800-3 
Emissions:EMC level C2 (3 phase), C1 (1 phase)
Protection Class:IP66 / Type 4X outdoor
Approvals: SIL3
VACON 20 X drives, 380 ÷ 480V, 3~ (3~MOTOR), IP66/Type 4X, EMC Class C2, No Keypad
SKU:DescriptionPower, [kW]Current, [A]Frame
VACON0020-3L-0003-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase0.752.4MU2
VACON0020-3L-0004-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase1.13.3MU2
VACON0020-3L-0005-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase1.54.3MU2
VACON0020-3L-0006-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase2.25.6MU2
VACON0020-3L-0008-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase37.6MU2
VACON0020-3L-0009-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase49MU3
VACON0020-3L-0012-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase5.512MU3
VACON0020-3L-0016-4-XVACON 20X drive, 380 ÷ 480V, IP66, 3~ phase7.516MU3

 VACON 20 X drives, 208 ÷ 230V, 1~ (3~MOTOR), IP66/Type 4X, EMC Class C1, No Keypad

SKU:DescriptionPower, [kW]Current, [A]Frame
VACON0020-1L-0004-2-XVACON 20X drive, 208 ÷ 230V, IP660.753.7MU2
VACON0020-1L-0005-2-XVACON 20X drive, 208 ÷ 230V, IP661.14.8MU2
VACON0020-1L-0007-2-XVACON 20X drive, 208 ÷ 230V, IP661.57MU2

DANFOSS – VACON 20 X drives, 208 ÷ 230V, 3~ (3~MOTOR), IP66/Type 4X, EMC Class C2, No Keypad

SKU:DescriptionPower, [kW]Current, [A]Frame
VACON0020-3L-0004-2-XVACON 20X drive, 208 ÷ 230V, IP66, 3~ phase0.753.7MU2
VACON0020-3L-0005-2-XVACON 20X drive, 208 ÷ 230V, IP66, 3~ phase1.14.8MU2
VACON0020-3L-0007-2-XVACON 20X drive, 208 ÷ 230V, IP66, 3~ phase1.57MU2
VACON0020-3L-0011-2-XVACON 20X drive, 208 ÷ 230V, IP66, 3~ phase2.211MU3
VACON0020-3L-0012-2-XVACON 20X drive, 208 ÷ 230V, IP66, 3~ phase312.5MU3
VACON0020-3L-0017-2-XVACON 20X drive, 208 ÷ 230V, IP66, 3~ phase417.5MU3