Products

136L4767 70-AB3L04605C10B540BM2H-00119243

    Name

    Email

    Phone

    Company Name

    Country

    Quantity

    Message

    Description

    70-AB3L04605C10B540BM2H-00119243

    VACON0100-3L-0460-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+DLNL+CIFD+EMAT+GNUL+GAAB

    Frequency converter
    VACON0100-3L-0460-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+DLNL+CIFD+EMAT+GNUL+GAAB
    VACON 100 FLOW
    380-500 Vac, 460 Amp,IP54/NEMA12
    Graphical Keypad MK01
    EMC C4 System Component
    B Slot: F3,3 Relay board
    C Slot: No board
    D Slot: No board
    E Slot: BJ,STO, ATEX therm
    Fieldbus: Std protocol,Modbus,N2,BacNet
    Manual: Dutch
    Frame 10

    Other options according to Model code

    Model code :
    VACON0100-3L-0460-5-ED-FLOW+SEBJ+IP54+EMC4+WT03+FL03+DLNL+CIFD+EMAT+GNUL+GAAB

    VACON® 100 AC drives are ideal for saving energy, optimizing process control and improving productivity. They are design.

    Gross weight 367.2 kg
    Net weight 366.2 kg
    Volume 0 l
    EAN 5710108813468

    VACON 0100
    Product View (Switch) GLBL Global (Standard)
    Segment -FLOW VACON 100 FLOW
    Region Code -R00 R00 International
    Mains voltage -5 380-500 Vac
    Current rating -0460 460 Amp
    Installation options -ED ED Enclosed Drive
    Enclosure +IP54 IP54/NEMA12
    Control panel +HMGR Graphical Keypad MK01
    EMC emission limit category +EMC4 EMC C4 System Component
    Common mode filter (for DM) +P000 No Option
    DUT filter (for DM) +P000 No Option
    Brake chopper +DBNO No dynamic braking device
    Real time clock option +SRNO No Battery for real time clock
    Configurable power range NONE None
    Power connections +P000 No Power options (+P000)
    Cable entry +Q000 No option
    Additional Equipment B +Q000 No option for Qxxx_B (+Q000)
    Additonal Equipment C +Q000 No additonal option for Qxxx_C
    Shipping package +GSWP Wooden box as shipping pack
    Marine construction +EMAT Marine testing, wo marine HW
    B-Slot Option Board +SBF3 F3,3 Relay board
    C- Slot Option Board +SC00 No board
    D-Slot Option Board +SD00 No board
    E-Slot Option Board +SEBJ BJ,STO, ATEX therm
    Internal FB selection +FBM1 Std protocol,Modbus,N2,BacNet
    Documentation level +DPAP Paper Manuals
    Document language preference +DLNL Dutch
    Firmware Language Pack +FL03 UK, ES, FR, IT, NL, PT lang
    Application +A0000 No Application
    Parameter Set +L0000 No application parameter set
    Motor parameter default freq +LS50 50 Hz def motor freq settings
    Unit for measure for display +LSSI Metric Units of Measure
    Labeling options +LPC1 no additional labels
    UL approval +GNUL No Ul Approval (+GNUL)
    Marine approval +GAAB American Bureau of Shipping
    RCM Approval +GACT (+GACT) RCM Approval N16307
    KC approval +GAKC KC Approval
    Ukrainian approval +GAUA Ukrainian Approval
    EAC Approval +GAEA EAC Approval
    Auxilary power supply +C000 no option (+C000)
    DC power supply for aux device +C000 no option (+C000)
    AC socket for aux devices +C000 no option (+C000)
    Input Devices +CIFD (+CIFD) Fuse Switch
    Common mode filter (for ED) +P000 no option
    DU/DT, Sine filter (for ED) +P000 no option
    Terminal Options +CTIO I/O Terminals (+CTIO)
    Door Equipments +C000 no option (+C000)
    Cabinet heater +C000 no option (+C000)
    Cabinet light +C000 no option (+C000)
    Motor heater control +C000 no option (+C000)
    Emergency stop options +C000 no option (+C000)
    Insulation fault sensor +C000 no option (+C000)
    Cabling from top +C000 no option (+C000)
    Back channel cooling +C000 no option (+C000)
    Cabinet Plinth +CHPL Base plint 100 mm
    Empty extension segment NONE None
    Standardized cabinet solution NONE None
    Engineered cabinet solution NONE None
    Product Group VACON VACON
    Product Series 0100 Vacon 100 series
    Phase -3L 3 Phase AC Input
    Customized +BM2H Vacon 100-FLOW
    Main Circuit +M000 NONE
    Firmware +F0159 Vacon0100-Flow Software pack
    Max output frequency NONE None
    Terminal Box +T000 NONE
    Bypass Control Operation Mode NONE none_
    Bypass Input Type NONE none_
    Bypass power connection type NONE none_
    CE approval +GACE CE Approval (+GACE)
    ATEX Approval NONE None
    County Specific Approval NONE None
    Warrenty time +WT03 Warranty 24/30 months (+WT03)
    Frame Size MR10 Frame 10
    Product Catalog NO_VIEW NO VIEW
    Modelcode01 VACON0100-3L-0460-5
    Modelcode02 -ED-FLOW+SEBJ+IP54+EMC4+WT03
    Modelcode03 +FL03+DLNL+CIFD+EMAT+GNUL
    Modelcode04 +GAAB
    Calculated Net Weight [kg] 379.4
    Calculated Gross Weight [kg] 380.4
    Motor Power Low Overload [kW] 250
    Dimensions WxHxD [mm] net 606 X 2155 X 639
    Dimensions WxHxD [mm] Gross 775 X 2435 X 880
    Continuous Current (NO) [A] 460
    Motor Power HP Low Overload 350
    Typecode Part 1 70-AB3L04605C10B540BM2H
    Typecode Part 2 -00119243
    Stockcode part 1 70-AB3L04605C10B540BM2H
    Stockcode part 2 -00119243
    check if complete OK
    Vendor ERR01 Cannot Determine Vendor
    Recommended Factory ERR01 Cannot Determine Vendor
    Help Counter 5
    Help Counter 4
    Calculated Net Weight 366.2
    Material Gross Weight 367.2
    Material Net Weight 366.2
    Salestext MR10-0460-5+IP54+EMC4
    Method HORIZONTAL
    Sub family identification NONE Normal customer ordered
    ECCN US 3A999.a
    ECCN EU X.A.I.003

    Reviews

    There are no reviews yet.

    Be the first to review “136L4767 70-AB3L04605C10B540BM2H-00119243”

    Your email address will not be published. Required fields are marked *